929 Series Pump Setting Gauge

929 Series Pump Setting Gauge

929 Series Pump Setting Gauge

929 Series Pump Setting Gauge

Applications

The 929 Series Pump Setting Gauge provides a means for checking the pumping rate of any chemical pump under actual pumping conditions in one minute. The gauge mounts in the pump’s suction line between the chemical storage tank and the pump. It provides a visual indication of the the liquid level in the tank in addition to a rapid means for setting the pump. Rate scale on the left side is marked and labeled in quarts per day and rate scale on the right side is labeled in Liters per Day.

The maximum pump rate for the 929 Series is 11.25 Gallons per Day or 42 Liters per Day, with each mark on the scale representing 1 Quart/1 Liter per 24 hours. Models are available with a coupler plug so that the unit can be easily disconnected for calibrating several chemical pumps.

Gallery

929 Series Pump Setting Gauge

Specifications

Model Number Basic Model Description *Maximum Pump Rate *Rate Scale Divisions Mounting Threads Vent Size Wetted Materials
929-1-S Gauge Only 11.25 GPD 929-1-S 1/4″ MNPT 1/4″ FNPT 303 S.S.
929-1-S-MRH 42 LPD 929-1-S
929-1-S6 Gauge Only 11.25 GPD 929-1-S 1/4″ MNPT 1/4″ FNPT 316 S.S.
929-1-16-MRH 42 LPD 929-1-S
929-2 929-1-S
2/COUPLER PLUG
11.25 GPD 929-1-S 1/4″ CPLR.
PLUG
1/4″ FNPT C.S. /303
S.S.
929-2-MRH 42 LPD 929-1-S
1061 QUICK COUPLER PLUG N/A N/A 1/4″ MNPT N/A C.S.
2037 929-2 COUPLER PLUG 1/4″ MNPT

*Maximum Pump Rates are based on a one minute test. Rate and Scale Divisions in Quarts Per Day/ Liters Per Day are based on a one minute test and Scale Divisions in Milliliters are based on gauge volume. 

Model 929-1-S

Gauge mounts in suction line between reservoir and chemical pump and allows you to accurately calibrate the pump to the desired amount of chemical to be injected. It provides a visual indication of liquid in the reservoir as well as a rapid means for setting the chemical pump. Rate scale on left side is marked in Quarts per Day and rate scale on right side is marked and labeled in Liters per Day.

  • 13″ Cast Aluminum Frame
  • No Test Valve
  • Wetted Parts 303 Stainless Steel, Aflas O-Ring Seals, and Glass
  • 1/4″ MNPT Mounting Thread
  • 1/4″ FNPT Vent
  • Each Division is Pump Rate of 1 Quart per Day / 1 Liter per Day

929-1-s-mmrh techdr(2)

Model 929-1-S6

Same as 929-1-S except with 316 Stainless Steel wetted metal parts

Model 929-1-S-MRH

Same as 929-1-S except with a clear polycarbonate sight tube shield with silk screened Metric Rate and Height scales. Scales are in Centimeters, Millimeters and Liters Per Day based on a one minute test.

  • 13″ Cast Aluminum Frame
  • No Test Valve
  • Wetted Parts 303 Stainless Steel, Aflas O-Ring Seals and Glass
  • 1/4″ MNPT Mounting Thread
  • 1/4″ FNPT Vent
  • Polycarbonate Metric Rate/Height Shield
  • Each Division is Pump Rate of 1 Quart per Day / 1 Liter per Day

Model 929-2

Same as 929-1-S except lower gauge connection is a 1/4″ quick disconnect plug meeting industrial Interchangeability requirements. This allows gauge to be easily moved to various quick disconnect coupler locations.

  • 13″ Cast Aluminum Frame
  • Coupler Plug for Movable Installation
  • No Test Valve
  • Wetted Parts 303 Stainless Steel/Carbon Steel, Aflas o-ring seals and Glass
  • 1/4″ Coupler Mounting Plug
  • 1/4″ FNPT Vent
  • Multiple Point Use
  • Each Division is Pump Rate of 1 Quart per Day / 1 Liter per Day